TECHNOLOGY VALUABLE SYSTEMS PTE., LTD

Broacast Solutions and Integration

Welcome Visitor you can Login / Register
 

Warning: include(/home/nusaeqer/public_html/wp-content/plugins/woocommerce/templates/shop/breadcrumb.php): failed to open stream: No such file or directory in /home/nusaeqer/public_html/wp-content/plugins/woocommerce/includes/wc-core-functions.php on line 249

Warning: include(): Failed opening '/home/nusaeqer/public_html/wp-content/plugins/woocommerce/templates/shop/breadcrumb.php' for inclusion (include_path='.:/opt/alt/php56/usr/share/pear:/opt/alt/php56/usr/share/php') in /home/nusaeqer/public_html/wp-content/plugins/woocommerce/includes/wc-core-functions.php on line 249
rcp-48lcd-oled-front

Magellan™ Control Panels

The Imagine Communications Magellan™ family of router control panels (RCPs) provides a fast, powerful and simple way to control your Imagine Communications or third-party routing systems. Available as a series of 10 programmable hardware panels in 1 or 2RU versions, Magellan RCPs offer intuitive, Web-based configuration — enabling the industry’s fastest setup for both local and remote operations.

These feature-rich, cost-effective and highly customizable panels — ranging from simple, button-per-source, single-bus panels to multilevel, multibus, relegendable LCD-button panels — are sure to meet both your budget and routing operational requirements. Designed with an understanding of the physical layout of a typical facility or OB truck, these compact RCPs — less than 2 inches deep — integrate easily into console-mount or any other space-constrained environment, enabling you to rapidly optimize the navigation and control of your routers.

Compare Products

Supports button-per-source (BPS), multibus, XY and enhanced grouping modes

Ability to reconfigure and reassign buttons and alias names both on panel front and at configuration GUI

Compact and less than 2-in. (51 mm) deep, ideal for console-mount applications

Supports Ethernet and coaxial connections

Ethernet supports both LRC (recommended) and XY protocols

Coaxial supports XY only (use these systems without a Platinum™ router or for legacy routers)

Common control sections

Web-based configuration for easy and fast setup

Unicode support

Template-based to facilitate quick configuration changes either at the panel or through the web

Automatic update of routing tables — no need for downloads

Parametric control of all Platinum modules for seamless router integration

Reviews

There are no reviews yet.

Be the first to review “Magellan™ Control Panels”

Specifications and designs are subject to change without notice.

RCP-24LCD-OLED
Number of Buttons 24 LCD plus 8 programmable function keys
Operation Modes Button-per-source, XY, grouping, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
RCP-48LCD-OLED
Number of Buttons 48 LCD plus 16 programmable function keys and 2 control knobs
Operation Modes Button-per-source, XY, grouping, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
RCP-32PB-OLED
Number of Buttons 32 push buttons plus 8 programmable function keys
Operation Modes Button-per-source, XY, multibus, single-bus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
RCP-64PB-OLED
Number of Buttons 64 push buttons plus 16 programmable function keys and 2 control knobs
Operation Modes Button-per-source, XY, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
RCP-16LCD
Number of Buttons 16 LCD plus 8 programmable function keys
Operation Modes Button-per-source, XY, grouping, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
RCP-32LCD
Number of Buttons 32 LCD plus 8 programmable function keys
Operation Modes Button-per-source, XY, grouping, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
RCP-64LCD
Number of Buttons 64 LCD plus 16 programmable function keys
Operation Modes Button-per-source, XY, grouping, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
RCP-16PB
Number of Buttons 16 push buttons plus 8 programmable function keys
Operation Modes Button-per-source, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
RCP-48PB
Number of Buttons 48 push buttons plus 8 programmable function keys
Operation Modes Button-per-source, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
RCP-96PB
Number of Buttons 96 push buttons plus 8 programmable function keys
Operation Modes Button-per-source, single-bus, multibus, breakaway
Communications Ports Ethernet and loop-through coaxial
Protocols Supported LRC (Ethernet only), XY (coaxial and Ethernet)
Dimensions (W x H x D) 19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)